Description
Victron Multiplus 12V 800VA 35-16A inverter
Multi functional
Parallel operation and three-phase option
Up to 6 Multiplus 12V 800VA 35-16A can work in parallel to reach the higher output power. In addition to parallel connection, three units of the same model can be configured for three phase output.
Uninterrupted AC power (UPS function)
In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
Following and short control
When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems’ locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website.
Access can be from a phone, tablet, laptop or PC for multiple operating systems. The level of the control doesn’t have any limits, from the adjustment of the Victron Multiplus 12V 800VA 35-16A inverter to the automatic start up of the reserved generator. And a lot more….
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years. The inverter is short-circuit proof and protected against overheating, either due to overload or high ambient temperature.
PowerControl – Dealing with limited generator, shore side or grid power
With the Multi Control Panel a maximum generator or shore current can be set. The Victron Multiplus 12V 800VA 35-16A will be responsible of the other AC chargers and use the left current for the charge avoiding this way the overcharge of the generator.
PowerControl – Dealing with limited generator, shore side or grid power
When it is necessary a power peak during a short period of time, like it happens a lot, the Victron Multiplus 12V 800VA 35-16A inverter will compensate immediately the lake of any power from the current or the generator. When the load reduces, the spare power is used to recharge the battery.
Four-stage variable charger and dual battery bank charging
The main output provides a powerful charge to the battery system through advanced “variable charging” software. Software fine-tunes the automatic three-stage process to suit battery conditions and adds a fourth stage for extended periods of float.
Moreover, the MultiPlus can charge a second battery using a separate limited charge output trying to charge a main engine or generator starting battery.
High start-up power
Required to start loads with a high inrush current, such as converters for LED lamps, halogen lamps or power tools.
Search mode
When this mode is on, the consumption of the inverter without any charge can decrease about 70%. Victron Multiplus 12V 800VA 35-16A inverter is off when it works as an inverter, it turns off when there is not any charge or there is just a little. It connects every 2 seconds during a short period of time.
If the output current exceed the established level, the inverter will be still working. If not, the inverter will shut down again.
Remote configuring
When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and settings can be changed remotely.
Data sheet of the Victron Multiplus 12V 800VA 35-16A inverter
See data sheet of the Victron Multiplus 12V 800VA 35-16A inverter